Side Fire Activation

Unistik® 3 safety lancet puts the sampling experience firmly in your hands, with side-fire activation enabling you to decide exactly when to activate the device and how much pressure to apply. The alignment guide indicates precisely where the device will activate on the patient’s finger.

Unistik® 3 - Safety Lancet - Benefits

  • Via an activation button and alignment guide.
  • Comfort Zone Technology™ maximises comfort for the patient during the sampling procedure².
  • Needle retracts immediately after use to reduce the risk of needlestick injuries.
  • Lock out indicator prevents reuse.
  • Lot number labelling providing traceability and peace of mind.
  • Side fire activation allows you to decide when to activate the device and how much pressure to apply.

Designed for Comfort

The Unistik® 3 safety lancet comes complete with Comfort Zone Technology minimizes the pain of finger sampling and gives you peace of mind.  When pressed against the sample site, a series of eight raised dots on the platform stimulate the nerve endings. This send a powerful message of comfort to the brain, masking the weaker pain stimulus from the needle¹.

Unistik® 3 - Range

BRAND DETAIL SUGGESTED
Unistik®3 Gentle 30 gauge lancet 1.5mm depth penetration Suggested patient areas e.g. pediatric and frequent testing
Unistik®3 Comfort 28 gauge lancet 1.8mm Suggested test areas e.g. ward blood glucose monitoring and HbA1C
Unistik®3 Normal 23 gauge lancet 1.8mm Suggested test areas e.g. ward blood glucose monitoring, cholesterol, HbA1C
Unistik®3 Extra 21 gauge lancet 2.0mm Suggested test areas e.g. cholesterol, Haemoglobin (Hgb), diagnostic kit tests such as cardiac enzymes
Unistik®3 Neonatal and Laboratory 18 gauge lancet 1.8mm

Neonatal suggested test areas e.g. congenital Hypothyroidism, Phenylketonuria (PKU), Single heelstick tests such as Bilirubin, Glucose, Haemoglobin, Sickle Cell disease and other diseases

Laboratory suggested test areas e.g. Blood Gases and Electrolytes, Chemistry Test Profiles, H.pylori

Jetzt Unistik® 3 kostenfrei testen!

Resources

Unistik® 3 Leaflet
Read more
Unifine® 3 Trainingskarte
Unifine® 3 Trainingskarte
Read more
Carte de formation U3
Unistik® 3 Prospekt
Unistik® 3 Prospekt
Read more
Unifine® 3 Kundeninformation
Unifine® 3 Kundeninformation
Read more
Unistik® 3 Instructions for use
Learn more
Unistik® Gesamtkatalog
Unistik® Gesamtkatalog
Read more
Unistik® 3 - Instruction For Use

Unistik® 3 - Instruction for Use

Watch
Unistik® 3 Neonatal

Unistik® 3 Neonatal

Watch
Unistik Comfort Zone Technology

Unistik® Comfort Zone Technology

Watch

References

  1. Melzack, R. and Wall, P. (1982).  The Challenge of Pain. England: Penguin Books.
  2. Dewland, P. and Edwards, C. (2007). A single-blind, randomised, 8-way crossover study to compare the blood volume and pain perception of capillary blood sampling. UK